Home Energy Audits: How to Read the Numbers and Choose What to Fix

An audit produces measurements, not a shopping list. The value comes from knowing which reading points to which problem, and which fix pays for itself.

An energy assessor setting up a blower door fan in a front doorway with gauges on a stand
An energy assessor setting up a blower door fan in a front doorway with gauges on a stand.

An energy audit is often sold as a report with a list of recommendations. That framing undersells the useful part. What an audit really produces is evidence: how leaky the building is, where heat escapes, how well the insulation performs, and how the heating and ventilation systems actually operate. The recommendations are only as good as the interpretation of those measurements.

This matters because houses are systems. Improving one element can make another worse. Adding insulation without ventilation can trap moisture. Sealing draughts without addressing combustion air can create a safety problem. A good audit identifies the interactions, then sequences the work so each measure improves the building rather than merely moving the problem.

The short version

  • Ask for measurements and assumptions, not just a list of recommendations.
  • Airtightness is measured in air changes per hour at 50 pascals; understand the unit before comparing results.
  • Thermal images show temperature, not moisture. Confirm every finding with a second method.
  • Fix the building envelope before replacing the heating system.
  • Compare measures by marginal cost per unit of energy saved, and account for comfort and durability.

What an audit should include

A domestic energy audit typically covers the building envelope, the heating and hot water systems, ventilation and, in a detailed assessment, air leakage and thermal performance. It may include a measured survey, a blower door test, thermal imaging, insulation checks in loft and cavities, and a review of controls and tariffs.

A domestic energy performance certificate is not an audit. It is a standardised rating based on assumptions about construction and services. It is useful for comparison and for compliance, but it does not measure your house. If you want to know where heat is actually escaping, you need measurements.

The blower door test

A blower door is a calibrated fan fitted into an external doorway. It depressurises the house and measures the airflow needed to maintain a pressure difference of 50 pascals. The result is expressed as air changes per hour at 50 pascals, or ACH50, which tells you how much of the house's air volume leaks out each hour under that test pressure.

The number is comparative, not a direct estimate of everyday draughts. A leaky older house might test at 10 to 15 ACH50; a new build might be designed for 5 or lower; a well-retrofitted house can reach 3 or below. The audit should also locate the leaks, using smoke pencils, thermal imaging or a pressure map, because the total figure alone does not tell you where to spend money.

Be careful with very low targets in older buildings. Airtightness must be paired with designed ventilation, or indoor air quality and moisture will suffer. The auditor should propose a ventilation strategy alongside the sealing work.

A thermal imaging camera screen showing heat loss around a loft hatch and ceiling joists
A thermal imaging camera screen showing heat loss around a loft hatch and ceiling joists.

Thermal imaging, read correctly

Thermal cameras detect surface temperature. In a heated house on a cold day, areas that are cooler than expected often indicate missing insulation, thermal bridging, air leakage or moisture. The image is a hypothesis generator, not a diagnosis.

A cold patch around a window may be a draught, a failed seal or a cold bridge at the frame. A dark band at the ceiling line may be missing insulation at the eaves. A cool patch on a wall may be damp, but it may also be a shadow or a cold pipe. Confirm with a moisture meter, a visual inspection or a second reading under different conditions.

Ask the assessor for the conditions during the survey: indoor and outdoor temperature, wind, and whether the heating was running. A thermal image taken on a mild, windy day tells you much less than one taken on a cold, still morning with a steady indoor temperature.

Insulation and airtightness checks

Loft insulation is easy to check and often found wanting. Measure the depth, check for gaps around joists, pipes and the loft hatch, and confirm that eaves ventilation is not blocked. Cavity insulation can be checked with a borescope through a small hole; it should fill the cavity evenly without voids or bridging.

Solid walls are harder. Internal or external insulation changes the moisture behaviour of the wall and must be designed with the right vapour control and breathability. An audit should flag where a simple product recommendation would be inappropriate.

MeasurementWhat it tells youCommon misinterpretation
ACH50Overall air leakage under testAssuming it equals everyday ventilation rate
U-valueHeat flow through an elementUsing declared values instead of as-built performance
Thermal imageSurface temperature differencesTreating every cold spot as damp
Heating flow temperatureHow hard the system is workingSizing a heat pump from the old boiler
Specific fan powerVentilation efficiencyIgnoring duct leakage

Ventilation and indoor air quality

As buildings get tighter, ventilation becomes more important. Moisture, cooking fumes, volatile organic compounds and carbon dioxide all need a route out. A simple extract fan in a bathroom is not a whole-house strategy. The audit should assess existing ventilation, identify where it is inadequate and propose a system that works with the planned airtightness.

Demand-controlled ventilation, mechanical ventilation with heat recovery, passive stack ventilation and improved natural ventilation all have a place. The right choice depends on the house, the climate, the occupants and the budget. Do not let an energy assessor specify a ventilation system without considering how the building will be used.

Close-up of an airtightness test gauge and clipboard with readings in a hallway
Close-up of an airtightness test gauge and clipboard with readings in a hallway.

Turning readings into a plan

List every measure with its capital cost, expected energy saving, disruption, lifespan and effect on comfort. Then rank by marginal cost per unit of energy saved, not by the headline saving. A measure that saves a lot but costs three times as much may be a worse use of money than two smaller measures combined.

Sequence matters. Envelope measures reduce the size of the heating system you need, so doing them first can lower the capital cost of the heat pump or boiler replacement. Ventilation should be designed alongside airtightness. Controls and tariffs should be addressed after the system is correctly sized.

  1. Safety and moisture first. Fix leaks, combustion safety, drainage and any active damp.
  2. Envelope next. Insulation, glazing, draught-proofing and airtightness with ventilation.
  3. Heating and hot water. Size for the improved load, not the old one.
  4. Controls and monitoring. Commission, explain and measure.
A reading without a location is trivia. A reading with a location, an interaction and a cost is a decision.

What the numbers do not capture

Comfort, health and durability matter even when they do not appear in a payback calculation. A warmer wall surface reduces condensation and mould. Better ventilation reduces damp and improves sleep. A quieter heating system is worth something. These benefits are real, and a purely financial ranking can miss them.

Conversely, a measure with a short payback may damage the building if it is wrong for the construction. External insulation on a heritage facade, internal insulation on a wall that needs to dry inwards, or airtightness without ventilation can all create expensive problems. The audit should say so.

An auditor inspecting loft insulation depth with a tape measure and torch
An auditor inspecting loft insulation depth with a tape measure and torch.

Common mistakes

  • Treating an EPC as a measured audit.
  • Comparing ACH50 results taken under different conditions.
  • Acting on a single thermal image without confirmation.
  • Insulating before fixing a leak or a ventilation problem.
  • Replacing the boiler or heat pump before reducing the heat load.
  • Ignoring the cost of disruption and making good.

What good looks like

A good audit gives you a measured baseline, a plan with costs and sequence, and a clear statement of uncertainty. It tells you what to do now, what to do when the roof is next replaced, and what not to do at all. It also gives you a way to verify the result after the work is complete.

Commission the audit before the quotations, not after. The measurements should shape the specification, not justify a decision already made.

A homeowner and assessor reviewing an energy report at a kitchen table with floor plans
A homeowner and assessor reviewing an energy report at a kitchen table with floor plans.

After the work is done

Repeat the key measurements. A second blower door test, updated thermal images and a season of energy monitoring will tell you whether the predicted savings appeared. If they did not, the data will show where the gap is: installation quality, occupant behaviour, a missed detail or an optimistic model.

Keep the audit and the post-work readings together. They are the building's energy history, and they are far more useful than a certificate when you come to sell, extend or replace a system.